-40%

Process Loop Calibrator Output 0-20mA Analog Transducer XMT -22mA Loop Power 24V

$ 162.09

Availability: 100 in stock
  • Model: VC05+
  • Country/Region of Manufacture: China
  • Brand: victor
  • Restocking Fee: No
  • Condition: New
  • All returns accepted: Returns Accepted
  • MPN: VC05+
  • Item must be returned within: 30 Days
  • Country of Manufacture: China
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer

    Description

    VC05
    Features:
    1. Basic accuracy 0.05%, display 5 digits.
    2. Measures DCV and DCA, and 24V loop power supply and current measurement.
    3. Output DCA and analogue transducer.
    4. Loop power 24V.
    5, Can display mA and %.
    6. Fast and slow 4-20mA auto slope wave output.
    Specifications:
    Output [ In one year, 23C±5C, 35-70%RH, accuracy= +-(seting%+words)]
    Output
    Range
    Detailed Range
    Resolution
    Accuracy
    Remarks
    DCI
    20mA
    0.000-22.000mA
    0.001mA
    0.05%+0.004mA
    20mA max. load 1KΩ
    XMT
    -20mA
    0.000 to -22.000mA
    0.001mA
    External power 5~28V, max. load 1KΩ
    Other characters:
    * Max.voltage for output: about 32Vpk; Max. current for output: about 5mA
    * Output protection: 63mA/250V fuse
    *Temperature
    coefficient: 0.1 x basic accuracy/C
    Measurement [ In one year, 23C±5C, 35-70%RH, accuracy= +-(seting%+words)]
    Measurement
    Range
    Detailed range
    Resolution
    Accuracy
    Remark
    DCI
    20mA
    -1.000-2.000mA
    0.001mA
    0.02%+0.004mA
    Input resisance 10Ω
    LOOP
    20mA
    -1.000-2.000mA
    0.001mA
    1. Input resisance 10Ω
    2. 24V loop power
    DCV
    28V
    -0.200

    28.000V
    0.001V
    0.02%+0.002V
    Input resisance 1MΩ
    Other characters:
    *Refresh rate: 2 times/second.
    * Max. voltage for input: 30Vpk; Max. current for input: 60mA
    *Current input protection: 63mA/250V
    *Input
    Common Mode Rejection
    :
    50Hz /60 Hz > 120dB;
    Input
    series mode rejection
    50Hz /60 Hz > 60dB
    * Temperature
    coefficient: 0.1 x basic accuracy/C
    Work temperature and RH
    0 to 50ºC, ≤80%RH; 40 to 50ºC, ≤70%RH
    Storage temperature and RH
    25 to 60ºC, ≤90%RH
    Conform to EN61010-1

    2001
    ; IEC 60068-2-64

    2008

    IEC 60068-2-32

    2008
    Power supply: 2 x 1.5V AA
    battery (Not included)
    Size and weight: 180 x90 x47
    mm; about 500g
    Accessories: a pair test leads, 63mA/250V
    fuse, PDF manual
    Note: we'll ship this item via
    express mail service
    to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia, Philippine, Singapore.
    Clients from other countries pls contact with us in advance to confirm the different shipping charges before you bid.