-40%

Fluke 743B Documenting Process Calibrator / Meter/Sourcemeter/Voltmeter/DMM+

$ 1319.99

Availability: 24 in stock
  • All returns accepted: ReturnsNotAccepted
  • Brand: Fluke
  • Condition: This unit has been fully tested and is guaranteed to work for 30-days, parts and labor, excluding freight.
  • MPN: 743B
  • Model: 743B
  • Calibrator Type: Process Calibrator

    Description

    Fluke 743B Documenting Process Calibrator
    Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it.
    Specifications are from Fluke and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    This unit has been fully tested and is guaranteed to work for 30-days, parts and labor, excluding freight.
    The Unit's Serial Number Tag Reads:
    Serial Number:
    7885008
    Software Version Information:
    Version:
    V1.3
    Boot:
    V1.2
    Capabilities:
    Source / Measure
    Automated procedures
    Results capture
    Uses all Fluke pressure modules
    Bar code entry
    Serial interface
    Data logging
    Transmitter mode
    Pulsed RTD simulation to 1 ms
    Brief Description:
    The
    Fluke 741B
    offers simultaneous source and measure capabilities for all common process parameters. Create and execute automated procedures and automatically capture the results.
    The
    Fluke 743B
    offers all the capability of the 741B, plus adds a serial interface for two-way communication with popular PC-based instrumentation management applications.
    DC Voltage Measurement Specifications:
    Range:
    Resolution:
    % of Reading + % of Full      Scale:
    1 Year:
    2 Year:
    110 mV
    1 µV
    0.025% + 0.015%
    0.05% + 0.015%
    1.1 V
    10 µV
    0.025% + 0.005%
    0.05% + 0.005%
    11 V
    100 µV
    0.025% + 0.005%
    0.05% + 0.005%
    110 V
    1 mV
    0.025% + 0.005%
    0.1% + 0.005%
    300 V
    10 mV
    0.025% + 0.005%
    0.1% + 0.005%
    Temperature Coefficient:
    (0.001% of rdg. + 0.0015% f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
    Input Impedance:
    5 MΩ
    Common Mode Error:
    0.008% f.s./(Common Mode Volt)
    Maximum Input Voltage:
    300 V rms
    AC Voltage Measurement Specifications:
    Frequency Range:
    % of Reading +      Number of Counts:
    1 Year:
    2 Year:
    20 Hz to 40 Hz
    2% + 10
    2% + 10
    40 Hz to 500 Hz
    0.5% + 5
    0.5% + 5
    500 Hz to 1 kHz
    2% + 10
    2% + 10
    1 kHz to 5 kHz
    10% + 20
    10% + 20
    Ranges:
    1.1000 V, 11.000 V, 110.00 V, 300.0 V rms
    Resolution:
    11.000 counts in all ranges except 300 V; 3,000 counts on 300 V range.
    Input Impedance:
    5 MΩ and < 100 pF
    Temperature Coefficient:
    10% of specification/°C in the ranges -10 to 18°C and 28 to 50°C
    Input Coupling:
    AC
    Maximum Input Voltage:
    300 V rms
    Maximum Input Voltage:
    0.5 V above 1 kHz
    Note:
    Specifications apply for 10% to 100% of voltage range.
    DC Current Measurement:
    Range:
    Resolution:
    % of Reading +      % of Full Scale:
    1 Year:
    2 Year:
    30 mA
    1 µA
    0.01% + 0.015%
    0.02% + 0.015%
    110 mA
    10 µA
    0.01% + 0.015%
    0.02% + 0.015%
    Temperature Coefficient:
    (0.001% of rdg. + 0.002% f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
    Common Mode Error:
    0.01% f.s./(Common Mode Voltage)
    Maximum Input Voltage:
    30 V dc
    Resistance Measurement Specifications:
    Range:
    Resolution:
    % of Reading +      ohms:
    1 Year:
    2 Year:
    11 Ω
    0.001 Ω
    0.05% + 0.05
    0.075% + 0.05
    110 Ω
    0.01 Ω
    0.05% + 0.05
    0.075% + 0.05
    1.1 kΩ
    0.1 Ω
    0.05% + 0.5
    0.075% + 0.5
    11 Ωk
    1 Ω
    0.1% + 10
    0.1% + 10
    Temperature Coefficient:
    (0.01% f.s. + 2 mΩ)/°C in teh ranges -10 to 18°C and 28 to 50°C
    Common Mode Error:
    0.005% f.s./(Common Mode Voltage)
    Maximum Input Voltage:
    30 V dc
    Continuity Testing:
    Tone:
    Resistance:
    Continuous tone
    < 25 Ω
    May or may not      get tone
    25 to 400 Ω
    No tone
    > 400 Ω
    Frequency Measurement Specifications:
    Ranges:
    Accuracy:
    1 Year:
    2 Year:
    1.00 Hz to      109.99 Hz
    0.05 Hz
    0.05 Hz
    110.0 Hz to      1099.9 Hz
    0.5 Hz
    0.5 Hz
    1.100 kHz to      10.999 kHz
    0.005 kHz
    0.005 kHz
    11.00 kHz to      50.00 kHz
    0.05 kHz
    0.05 kHz
    Minimum Amplitude for Frequency Measurement (square wave):
    <1 kHz:
    300 mV p-p
    1 kHz to 30 kHz:
    1.4 V p-p
    > 30 kHz:
    2.8 V p-p
    Maximum Input:
    < 1 kHz:
    300 V rms
    > 1 kHz:
    30 V rms
    Input Impedance:
    5 MΩ
    Notes:
    For frequency measurement less than 109.99 Hz, specifications apply for signals with a slew rate greater than 5 volt/millisecond.
    DC Voltage Output Specifications:
    Range:
    Resolution:
    % of      Output + % of Full      Scale:
    1 Year:
    2 Year:
    110 mV
    1 µV
    0.01% + 0.005%
    0.015% + 0.005%
    1.1 V
    10 µV
    0.01% + 0.005%
    0.015% + 0.005%
    15 V
    100 µV
    0.01% + 0.005%
    0.015% + 0.005%
    Temperature Coefficient:
    (0.001% of output + 0.001% of f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
    Maximum Output Current:
    10 mA
    Loading:
    (0.001% f.s. + 1 µV)/mA
    Common Mode Error:
    0.008% f.s./(Common Mode Voltage)
    Maximum Input Voltage:
    30 V dc
    DC Current Output:
    Range/Mode:
    Resolution:
    % of      Output + % of Full      Scale:
    1 Year:
    2 Year:
    22 mA/Source mA
    1 µA
    0.01% + 0.015%
    0.02% + 0.015%
    22 mA/Simulate      Transmitter (Current Sink)
    1 µA
    0.02% + 0.03%
    0.02% + 0.03%
    Maximum Burden Voltage:
    24 V
    Temperature Coefficient:
    (0.003% of output + 0.003% of f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
    Common Mode Error:
    0.008% f.s./(Common Mode Voltage)
    Maximum Input Voltage:
    30 Vdc
    Notes:
    Specification applies for currents between 2 mA and 22 mA. For current below 2 mA, typical accuracy is 0.15% of full scale.
    Resistance Sourcing Specifications:
    Range:
    Resolution:
    % of      Output + % of ohms:
    1 Year:
    2 Year:
    11.000
    1 m
    0.01% + 0.02
    0.02% + 0.02
    110.00
    10 m
    0.01% + 0.04
    0.02% + 0.04
    1.1000 k
    100 m
    0.02% + 0.5
    0.03% + 0.5
    11.000 k
    1
    0.03% + 5
    0.04% + 5
    Temperature Coefficient:
    (0.01% of f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
    Maximum and Minimum Current through Source Resistance:
    11 Ω Range:
    3 mA dc max, 0.1 mA dc min
    110 Ω Range:
    3 mA dc max, 0.1 mA dc min
    1.1 kΩ Range:
    3 mA dc max, 0.01 mA dc min
    11 kΩ Range:
    1 mA dc max, 0.01 mA dc min
    Common Mode Error:
    0.008%/f.s./(Common Mode Voltage)
    Maximum Input Voltage:
    30 V dc
    Frequency Sourcing Specifications:
    Range:
    % of Output + % of      ohms:
    1 and 2      Year:
    0.00 Hz
    0.01 Hz
    11.00 Hz to      109.99 Hz
    0.1 Hz
    110.0 Hz to      1099.9 Hz
    0.1 Hz
    1.100 kHz to      21.999 kHz
    0.002 kHz
    22.000 kHz to      50.000 kHz
    0.005 kHz
    Waveform Choices:
    Zero-symmetric sine or positive square wave, 50% duty cycle.
    Amplitude:
    0.1 to 10 V pk
    Amplitude Accuracy:
    0 Hz to 1099 Hz:
    3% of output + 0.5% f.s.
    1.1 kHz to 10.9 kHz:
    10% of output + 0.5% f.s.
    11 kHz to 50 kHz:
    30% of output + 0.5% f.s.
    Maximum Input Voltage:
    30 V dc
    Temperature Thermocouples Specifications:
    Type:
    Range °C:
    Measures °C:
    Source °C:
    1 Year:
    2 Year:
    1 Year:
    2 Year:
    E:
    -250 to -200
    1.3
    2.0
    0.6
    0.9
    -200 to -100
    0.5
    0.8
    0.3
    0.4
    -200 to -100
    0.5
    0.8
    0.3
    0.4
    600 to 1000
    0.4
    0.6
    0.2
    0.3
    N:
    -200 to -100
    1.0
    1.5
    0.6
    0.9
    -100 to 900
    0.5
    0.8
    0.5
    0.8
    900 to 1300
    0.6
    0.9
    0.3
    0.4
    J:
    -210 to -100
    0.6
    0.9
    0.3
    0.4
    -100 to 800
    0.3
    0.4
    0.2
    0.3
    800 to 1200
    0.5
    0.8
    0.2
    0.3
    K:
    -200 to -100
    0.7
    1.0
    0.4
    0.6
    -100 to 400
    0.3
    0.4
    0.3
    0.4
    400 to 1200
    0.5
    0.8
    0.3
    0.4
    1200 to 1372
    0.7
    1.0
    0.3
    0.4
    T:
    -250 to -200
    1.7
    2.5
    0.9
    1.4
    -200 to 0
    0.6
    0.9
    0.4
    0.6
    0 to 400
    0.3
    0.4
    0.3
    0.4
    B:
    600 to 800
    1.3
    2.0
    1.0
    1.5
    800 to 1000
    1.0
    1.5
    0.8
    1.2
    1000 to 1820
    0.9
    1.3
    0.8
    1.2
    R:
    -20 to 0
    2.3
    2.8
    1.2
    1.8
    0 to 100
    1.5
    2.2
    1.1
    1.7
    100 to 1767
    1.0
    1.5
    0.9
    1.4
    S:
    -20 to 0
    2.3
    2.8
    1.2
    1.8
    0 to 200
    1.5
    2.1
    1.1
    1.7
    200 to 1400
    0.9
    1.4
    0.9
    1.4
    1400 to 1767
    1.1
    1.7
    1.0
    1.5
    C:
    0 to 800
    0.6
    0.9
    0.6
    0.9
    800 to 1200
    0.8
    1.2
    0.7
    1.0
    1200 to 1800
    1.1
    1.6
    0.9
    1.4
    1800 to 2316
    2.0
    3.0
    1.3
    2.0
    L:
    -200 to -100
    0.6
    0.9
    0.3
    0.4
    -100 to 800
    0.3
    0.4
    0.2
    0.3
    800 to 900
    0.5
    0.8
    0.2
    0.3
    U:
    -200 to 0
    0.6
    0.9
    0.4
    0.6
    0 to 600
    0.3
    0.4
    0.3
    0.4
    Resolution:
    0.1°C
    Temperature Scale:
    ITS-90 or IPTS-68, selectable
    Compensation:
    ITS-90 per NIST Monograph 175 for B, R, S, E, J, J, B, T; IPTS-68 per IEC 584-1 for B, R, S, E, J, K, T; IPTS-68 per DIN 43710 for L, U.
    Temperature Coefficient:
    0.05°C/°C in the range -10 to 18°C and 28 to 50°C
    Common Mode Error:
    0.01°C/(Common Mode Voltage)
    Maximum Input Voltage:
    30 V
    Notes:
    Sensor inaccuracies not included. Accuracy with external cold junction; for internal injunction add 0.2°C.
    Temperature, Resistance Temperature Detectors Specifications:
    Type (
    α
    ):
    Range °C:
    Measure °C:
    Source °C:
    1 Year:
    2 Year:
    1 Year:
    2 Year:
    100 Ω Pt (3926):
    -200      to 0
    0.3
    0.4
    0.1
    0.2
    0      to 630
    0.5
    0.8
    0.2
    0.4
    100 Ω Pt(385):
    -200 to 0
    0.3
    0.5
    0.1
    0.2
    0      to 400
    0.5
    0.8
    0.2
    0.4
    400      to 800
    0.8
    1.0
    0.4
    0.5
    120 Ω Ni(672):
    -200 to 260
    0.3
    0.4
    0.1
    0.2
    200 Ω Pt(385):
    -200 to 0
    0.3
    0.5
    0.1
    0.2
    0      to 400
    0.5
    0.8
    0.2
    0.4
    400      to 630
    0.8
    1.0
    0.4
    0.5
    500 Ω Pt(385):
    -200 to 0
    0.3
    0.5
    0.1
    0.2
    0      to 400
    0.5
    0.8
    0.2
    0.4
    400      to 630
    0.8
    1.0
    0.4
    0.5
    1000 Ω Pt(385):
    -200 to 0
    0.3
    0.5
    0.1
    0.2
    0 to 400
    0.5
    0.8
    0.2
    0.4
    400 to 360
    0.8
    1.0
    0.4
    0.5
    10 Ω Cu(427):
    -100 to 0
    2
    2
    1
    1
    0 to 260
    2
    2
    1
    1
    100 Ω Pt(3916):
    -200 to -190
    0.3
    0.4
    0.3
    0.4
    -190 to 0
    0.3
    0.4
    0.1
    0.2
    800 to 1200
    0.5
    0.8
    0.2
    0.4
    Resolution:
    0.1°C
    Temperature Coefficient:
    0.02°C/°C in the ranges -10 to 18°C and 28 to 50°C
    Maximum Input Voltage:
    30 V
    Maximum Input Current for RTD Source:
    10 Ω RTDs:
    8 mA dc
    100 Ω - 120Ω RTDs:
    3 mA dc
    200 &Omega - 1000 Ω RTDs:
    1 mA dc
    Notes:
    Sensor inaccuracies not included. For two and three-wire RTD measurements, add 0.4°C to the specifications.
    General Specifications:
    Display:
    240 x 200 pixel graphic LCD, 70 x 58 mm.
    Power:
    Internal battery pack: NiCd, 7.2 V, 1700 mAh
    Memory Backup:
    Lithium battery, 5 years typical lifetime.
    Dimensions:
    130 x 236 x 61 mm (5.1 x 9.3 x 2.4 in).
    Weight:
    1.4 kg (3 lb. 1 oz.)
    Altitude:
    Up to 2800 meters (9186 ft) above mean sea level.
    Operating Temperature:
    -10 to 50°C (typically to -20°C, except for frequency measure and ac voltage measure)
    Storage Temperature:
    -20 to 60°C
    Humidity:
    Avoid prolonged use outside the safe operating boundaries shown in the graph in the manual.
    Water/Dust Protection:
    Designed to meet IEC529 IP52 (normal operating vacuum used for dust test.)
    Safety:
    Designed in accordance with ANSI/ISA-S82 .01-1994, UL3111, CAN/CSA C22.2 No. 1010.1-92, and EN610-10:1993.
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    02/13/13