-40%

Fluke 726 Precision Multifunction Process Calibrator

$ 1848

Availability: 100 in stock
  • Modified Item: No
  • All returns accepted: ReturnsNotAccepted
  • Custom Bundle: No
  • MPN: 2452080
  • Condition: NEW - ONLY OPEN WITH NO USE.
  • Brand: Fluke
  • Country/Region of Manufacture: Unknown
  • Calibrator Type: Process Calibrator

    Description

    Fluke 726 calibrator, one set of AC72 crocodile clips, one set of expandable test leads, one set of TL 75 test leads, user manuals.
    Automated production line used in manufacturing, and other industries, can function at high efficiency only in ensuring accuracy and reliability of information from the sensors and transducers which, in fact, are the key elements of the AMS.
    Therefore, when precision sensors are calibrated, it is imperative to use high-precision tools. The multifunctional process calibrator Fluke 726 has the highest accuracy among similar devices of its class, and at the same time it features high functionality and versatility,
    so you can use it to calibrate almost any sensors and converters used in industrial automation systems.
    Features of the Fluke 726 multifunction calibrator
    Calibrator Fluke 726 allows you to perform all tasks solved with the help of the younger model Fluke 725, and besides this:
    provides greater accuracy in measuring and simulating signals, which can be used to calibrate precision sensors;
    allows you to determine the error of the sensors being checked (you do not need to perform additional calculations with the calculator);
    can be used to calibrate frequency meters,
    modeling the frequency sequence of pulses, without the use of a separate generator or a specialized calibrator;
    It makes possible to check HART devices, thanks to the built-in resistor, which is connected to the measuring circuit if necessary;
    saves up to 8 calibration results in memory,
    which you can analyze in more detail after the end of the measurements;
    checking thermal converters, can use user temperature dependencies and calibration constants in the course of extended measurements, which provides a higher flexibility for the application of this calibrator.
    Fluke 726
    Direct current voltage
    30000 V 0.01% + 2 units (top of the display)
    30000 V 0.01% + 2 units (lower part of the display)
    100 mV 0.01% + 2 units
    from -10 mV to 75 mV 0.025% + 1 unit (via the TC-connector)
    D.C
    24,000 mA 0.01% + 2 units
    Resistance
    from 0 to 4000 Ohm +/- 0.015%
    Frequency
    from 2.0 to 1000 CPM 0.05% + 0,
    1 unit
    from 1.0 to 1000 Hz 0.05% + 0.1 Hz
    from 1 to 15.0 kHz 0.05% + 0.1 kHz
    from 10 to 15.0 kHz 0.05% + 1 unit
    Sensitivity A minimum of a double amplitude of 1 V
    Pressure
    Accuracy from 0.025% of the range when using any of the 29 pressure modules. (for detailed specifications,
    pressure modules in additional equipment and accessories) There are modules for differential, gauge, absolute, double, high pressure and for vacuum.
    Excitation accuracy
    Direct current voltage
    100 mV 0.01% + 2 units
    10000 V 0.01% + 2 units
    from -10 mV to 75 mV 0.025% + 1 unit (via the TC-connector)
    D.C
    24,
    000 mA (source) 0.01% + 2 units
    24,000 mA (imitation) 0.01% + 2 units
    Resistance
    Range from 5 to 400 Ohm
    from 5 to 400 ohm
    from 400 to 1500 ohms
    from 1500 to 4000 Ohm
    Accuracy Percentage of value + basic error
    0.015% + 0.1 Ω
    0.015% + 0.05 Ohm
    0,015% + 0,5 Ohm
    0,015% + 0,5 Ohm
    Excitation current from 0.1 to 0.5 mA
    from 0,5 to 3 mA
    0.05 to 0
    , 8 mA
    from 0.05 to 0.4 mA
    Frequency
    from 2.0 to 1000 CPM 0.05%
    from 1.0 to 1100 Hz 0.05%
    from 1.00 to 10.00 kHz 0.25%
    from 10 to 15.0 kHz 0.5%
    Signal form: Straight line. a double amplitude pulse of 5 V, a deviation of -0.1 V
    Pulse RTD transmitters and thermocouples
    Measurement and excitation accuracy:
    Cu10 1.8 ° C
    NI-120 0.15 ° C
    PT-100 (385) 0.25 ° C
    PT-100 (392) 0,
    15 ° C
    PT-100 (391-JIS) 0.25 ° C
    PT-200 (385) 0.75 ° C
    PT-500 (385) 0.35 ° C
    PT-1000 (385) 0.15 ° C
    Solution: 0.01 ° C
    J: 0.4 ° C
    K: 0.5 ° C
    T: 0.4 ° C
    E: 0.4 ° C
    R: 1.4 ° C
    S: 1.4 ° C
    B: 1.4 ° C
    L: 0.45 ° C
    U: 0.45 ° C
    N: 0.6 ° C
    XK: 0.4 ° C
    BP: 1.1 ° C
    Resolution J, K, T, E, L, N, U: 0,1 ° C, 0,1 ° F B, R, S: 1 ° C, 1 ° F
    Features
    Linear-increasing functions
    Excitation functions: Voltage, current, resistance, frequency, temperature
    Linear Change Functions The function of slow, fast (ramp) linear change, stepping function (25% step)
    Network power function
    Voltage: 24 V
    Accuracy: 10%
    Maximum current: 22 mA, short circuit protection
    Step functions
    Excitation functions: Voltage, current, resistance, frequency, temperature
    Steps 25% of the range, 100% of the range
    Environmental requirements
    Operating temperature -10 ° C to + 55 ° C
    Storage temperature from -20 ° C to + 71 ° C
    Height above sea level during operation 3000 m
    Electrical safety standard
    The received approvals of EN 61010-1: 1993,
    ANSI / ISA S82.01-1994; CAN / CSA C22.2 No 1010.1: 1992
    Mechanical and general characteristics
    Size 200 mm x 96 mm x 47 mm (7.9 in x 3.8 in x 1.9 in)
    Weight 650 g (23 oz)
    Batteries 4 AA alkaline batteries
    Replacement of batteries Separate battery compartment for changing the battery without violating the calibration mark
    Connections to the harbor port The pressure block connector, also used for remote programming in real time
    Shipping
    Expedited shipping DHL 5-15
    days.
    PAYMENT