1nA-10A 1mkV-10V 0.02% P321 Calibrator Voltage & Current Standard an-g of FLUKE

$ 1235.75

Availability: 12 in stock
  • Condition: New – Open box
  • Model: P321
  • Brand: P321

    Description

    High Precision P321 Multivalued Programable Voltage & Current Calibrator analog of FLUKE,EDC,Agilent,Tektronix
    IET Labs, but has the same or better characteristics.
    P321 is
    designed
    for use
    in automated
    calibration
    units
    , as well
    as separate
    device
    for testing
    of
    analog and digital
    DC devices.
    P321
    calibrator
    provides:
    -
    calibrated
    voltage
    range
    10
    -5
    - 10 V;
    -
    calibrated
    current
    range
    10
    -9
    - 10 A;
    - remote
    management, including setting
    limits
    and the level of
    the output parameters;
    - level control
    of
    the output parameter
    in
    BCD
    8-4-2-1;
    Power supply:
    220V, 50 Hz;
    Power consumption
    :
    500
    V*A;
    The average service
    10 years;
    Dimensions
    :
    Power
    controller
    488х535х250
    mm;
    Power supply
    488х535х170
    mm;
    Weight:
    Power
    controller
    25  kg;
    Power supply
    20kg.
    Accuracy of the calibrator II321 (P321,
    П
    321) in the different ranges:
    Calibrated Voltage limits (currents)
    Error limits of calibrated voltage values (currents)
    Max. permissible error for calibrated voltages (currents)
    10
    mkA
    ± (0,1 · I к + 1) nA
    ± [ 10 · Iк(0,01 + g
    НЭ
    +g
    RN
    )+2 ] nA
    100
    mkA
    ± (0,05 · Iк+1) nA
    ± [ 10 · Iк(0,005 + g
    НЭ
    +g
    RN
    )+1 ] nA
    1 mA
    ±(0,05·Iк+0,01)
    mkA
    ±[10·Iк(0,005+g
    НЭ
    +g
    RN
    )+0,01] mkA
    10  mA
    ±(0,05·Iк+0,1)
    mkA
    ±[10·Iк(0,005+g
    НЭ
    +g
    RN
    )+0,1] mkA
    100 mA
    ±(0,05·Iк+1) mkA
    ±[10·Iк(0,005+g
    НЭ
    +g
    RN
    )+1]
    mkA
    1 A
    ±(0,1·Iк+0,05) mA
    ±[10·Iк(0,01+g
    НЭ
    +g
    RN
    )+0,05] mA
    10 A
    ±(0,1·Iк+0,5) mA
    ±[10·Iк(0,01+g
    НЭ
    +g
    RN
    )+0,5] mA
    1 V
    ± (30 · Uк+10) mkV
    ± [ 30 · Uк + g
    НЭ
    · Uk · 10
    4
    +10 ] mkV
    10 V
    ± (20 · Uк+50) mkv
    ± [ 20 · Uк + g
    НЭ
    · Uk · 10
    4
    +50 ] mkV
    Warranty 12 month.
    This device was also used in USSR and Russian army. So it has best quality
    ,
    longevity, and permanence characteristic.
    Condition:
    NEW (not used, but from an old stock). Tested and 100% workable.
    If necessary, the device can be calibrated and provided with the calibration certificate
    from Government Standardization Institute ( +145-265usd).
    P321 Multivalued Programable Voltage & Current Calibrator
    is analog
    device of such manufactures as
    FLUKE,EDC,Agilent, LEEDS & NORTHRUP, ESI (Electro Scientific Industries), Honeywell, IET Labs, JAME G BIDDLE CO, GRAY INST, TEGAM, Guildline, Tektronix, Fluke and others.
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Please take a look on my other items!
    If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
    This device  can be also named as:
    P321, P-
    321
    , P
    321
    , R
    321
    , R
    321
    , R-
    321
    , р
    321
    , р-
    321
    , р
    321
    ,
    П
    321,
    П
    -321,
    П
    321, II321 II 321 II-321,
    calibrator, standart calibrator, controller, programable calibrator,
    voltage calibrator, current calibrator.
    Technical characteristics:
    Programmable current calibrator
    P321
    (P 321, P-321)
    P321 is
    designed
    for use
    in automated
    calibration
    units
    , as well
    as separate
    device
    for testing
    of
    analog and digital
    DC devices.
    Dimensions
    488x250x535mm
    (
    control block),
    488x170x535
    (
    power supply unit
    )
    Programmable current calibrator
    s
    P321
    are used as precision
    calibrated
    sources of
    current and voltage
    with manual and
    programmed control
    and are designed
    for use
    in automated
    calibration
    units
    , as well
    as separate
    device
    for testing
    of
    analog and digital
    DC devices. The ability of programmable
    control
    allows to use
    Programmable current calibrator
    P321
    in automated
    measurement systems
    and calibration
    devices.
    Programmable current calibrator
    P321
    is
    designed to operate
    at a temperature of
    10-35 °
    C and relative
    humidity of
    80%
    at 25 °
    C.
    Calibrator
    Power supply
    -
    AC
    220 V,
    frequency 50 Hz
    or 60
    Hz.
    Programmable current calibrator
    P321
    designed
    for areas with
    tropical climate
    (marked as
    -
    P321 04.1хх
    ), should
    operate
    in air-conditioned rooms
    at temperature
    10-35 °
    C and relative
    humidity of
    80%
    at 25 °
    C.
    Technical characteristics
    Programmable current calibrator
    P321
    provides calibrated
    current in
    range from
    10
    -9
    A
    to 10A
    with final values
    10mkA
    ,
    100mkA
    ,
    1mA
    , 10mA,
    100mA
    ,
    1A and
    10A
    (
    KT
    mode
    ) and
    calibrated
    voltage in
    range from
    10
    -5
    V
    to 10V
    with the
    final values
    1V and
    10V
    (KN
    mode
    );
    Current and voltage
    calibrated
    values
    are shown
    on the screen.
    Calibrated current
    setting resolution
    1 nA-
    on ranges
    with final values
    10mkA
    ,
    100mkA
    and
    1mA
    ,
    10nA
    , and
    100nA
    ,
    1 mkA
    and
    10mkA
    -
    on ranges
    with final values
    of
    10, 100
    mA and
    1, 10
    A
    .
    Calibrated
    voltage
    setting resolution
    -
    10mkV
    Programmable current calibrator
    P321
    can be controlled manually
    by
    switchers, located on the
    front panel
    or
    by commands from
    an external
    terminal
    YP
    .
    Programmed control
    provides:
    turn on and
    turn off
    calibrator on commands
    "Start"
    and "
    Reset";
    installation of final value
    range
    and level of
    the calibrated
    current (voltage)
    according to Table
    1.
    Output current
    (voltage) level
    managing is provided in
    binary-
    decimal code
    8-4-2-1
    ,
    commands
    are realized
    by logical signal
    "1
    " on the
    clamp
    "╧". Logical
    signal "1"
    corresponds to voltage level
    from 2.4
    to 5.25
    V.
    Logical signal
    "0
    " corresponds to
    voltage level
    from -0.4
    to +0.5
    V.
    Calibrator
    output
    disconnection
    to
    command "
    reset"
    is accompanied by
    the presence of
    logical signal
    "1"
    on the contact
    "
    P"
    connector
    YP
    .
    Acceptable basic error of calibrators values limits in  calibrated current and voltage mode and acceptable basic error values limits of voltage and current calibrated values  correspond to those indicated in the Table 2. Acceptable basic error limits for 3 months of work correspond to those indicated in Table 3.
    Calibrators
    setup time to operating mode is
    not more than 1
    hour. Calibrators
    continuous operating
    time without
    setting operating mode in working conditions is
    at least 8
    hours. Calibrators re-enable
    interval
    time
    is
    at least
    1 hour.
    Calibrated
    current (voltage
    )
    instability
    ,
    caused by calibrators internal
    fluctuation
    noise
    does not exceed
    values given
    in Table 4.
    Rms
    value level of variable
    component
    at calibrators output in frequency ranges up to
    1 MHz
    does not exceed
    the values given
    in Table.
    4.
    Calibrators acceptable basic error
    ,
    caused by ambient temperature changes
    from performing temperature,
    to any temperature
    within operating one
    for each 10
    °
    C,
    is
    equal to the acceptable
    basic error
    limit
    in all ranges
    , except
    ranges with
    final values
    1 and
    10 A,
    where it should be
    equal to twice
    acceptable
    basic error limit.
    Programmable current calibrator
    P321
    provides  voltage at load in KH mode and load current in mode KH according to the table 5. Calibrators acceptable additional error limit, caused by voltage changes at load from 10% to valid value in mode KN, is equal to acceptable basic error limit.
    Calibrator acceptable
    additional error limits
    ,
    caused by current load changes
    from 10% to
    valid value
    in mode KN are equal to acceptable
    basic error limit.
    Adjustment elements reserve
    required for
    calibration (
    KALIBR.
    Uop, GRYBO
    ,
    Ust.0
    ),
    at calibrators release
    is at least 20
    % of
    the control range
    .
    Time to establish
    calibrated
    current with
    error do not exceed
    values ​​shown
    in Table.
    2,for
    less than
    5 seconds.
    Electrical
    resistance between
    terminal
    "╧"
    and calibrator case is not more than
    0.5 Ω.
    Insulation
    between case (terminal
    "╧")
    and network 220V
    stands
    for 1 minute
    AC voltage
    test effect with frequency 50
    Hz and current
    value of
    1.5 kV
    .
    Insulation resistance
    between case
    and isolated schemes
    parts and
    insulation resistance
    between isolated
    schemes parts  correspond to values
    shown
    in Table 6.
    Current
    calibrator
    is supplied from
    the AC
    voltage
    (
    220+22
    )V with
    frequency
    (
    50+1
    )
    or
    Hz
    (60
    ± 1.2)
    Hz.
    Calibrators network power consumption,
    at a nominal
    voltage supply do not exceed
    350 V•A
    Current calibrator
    P321
    temperature resistant
    at a temperature of
    60 °
    C and
    cold resistand
    at -50 °
    C.
    Current calibrator
    P321
    waterproof within
    relative humidity
    95%
    at 40 °
    C.
    Calibrators
    blocks
    dimensions and weight
    do not exceed those
    shown
    in table 7.
    Table 1
    Commands title
    Contact
    connector
    YP
    Start
    А
    Reset
    P
    Final value measurement range
    setting
    10mkA
    С
    100mkA
    Т
    1mA
    U
    10mA
    Х
    100mA
    CE
    1A
    12
    10A
    13
    1V
    F
    10V
    17
    Output current
    (voltage
    )
    level setting
    :
    8 · 10
    -1
    B
    4 · 10
    -1
    V
    2 · 10
    -1
    G
    1 · 10
    -1
    D
    8 · 10
    -2
    Е
    4 · 10
    -2
    J
    2 · 10
    -2
    Z
    1 · 10
    -2
    I
    8 · 10
    -3
    К
    4 · 10
    -3
    L
    2 · 10
    -3
    М
    1 · 10
    -3
    N
    8 · 10
    -4
    5
    4 · 10
    -4
    6
    2 · 10
    -4
    7
    1 · 10
    -4
    8
    8 · 10
    -5
    9
    4 · 10
    -5
    10
    2 · 10
    -5
    11
    1 · 10
    -5
    15
    8 · 10
    -6
    16
    4 · 10
    -6
    18
    2 · 10
    -6
    19
    1 · 10
    -6
    21
    Note
    .
    Command title
    "
    Output current
    (voltage
    ) setting "
    indicates parameter of
    value
    installed in units
    of selected
    calibrated
    current or voltage final value
    range
    .
    Table 2
    Final value of
    current (voltage)calibrated
    range
    Acceptable
    accuracy limit of
    current (
    voltage)
    calibrated
    relative value
    Calibrators acceptable
    basic accuracy limit in
    calibrated
    current (
    voltage)
    mode
    10mkA
    ± (0,1 · Ік + 1) nA
    ± [10 · Ік (0,01 + γ
    ne
    + γ
    RN
    ) + 2] nA
    100mkA
    ± (0,05 · Ік + 1) nA
    ± [10 · Ік (0,005 + γ
    ne
    + γ
    RN
    ) + 1] nA
    1мА
    ± (0,05 · Ік + 0,01) mkA
    ± [10 · Ік (0,005 + γ
    ne
    + γ
    RN
    ) + 0,01] mkA
    10mA
    ± (0,05 · Ік + 0,1) mkA
    ± [10 · Ік (0,005 + γ
    ne
    + γ
    RN
    ) + 0,1] mkA
    100mA
    ± (0,05 · Ік + 1) mkA
    ± [10 · Ік (0,005 + γ
    ne
    + γ
    RN
    ) + 1] mkA
    1A
    ± (0,1 · Ік + 0,05) mA
    ± [10 · Ік (0,01 + γ
    ne
    + γ
    RN
    ) + 0,05] mA
    10A
    ± (0,1 · Ік + 0,5) mA
    ± [10 · Ік (0,01 + γ
    ne
    + γ
    RN
    ) + 0,5] mA
    1V
    ± (30 · Uк + 10) mkV
    ± [30 · Uк + γ
    ne
    · Uк · 10
    4
    + 10] mkV
    10V
    ± (20 · Uк + 50) mkV
    ± [20 · Uк + γ
    ne
    · Uк · 10
    4
    + 50] mkV
    Note:
    1
    .
    Ik
    (
    Uk) -
    a dimensionless quantity
    that is numerically
    equal to specified calibrated current value
    in
    mkA,
    mA
    and
    A
    on appropriate
    ranges
    (
    value
    set by
    calibrated
    V
    ).
    2
    .
    γne
    and
    γRN -
    dimensionless quantities
    are numerically equal to accuracy
    class
    of normal element
    and electrical resistance measurements
    ,
    used for
    calibration.
    3
    .
    Acceptable
    basic error limits
    for given
    load, do
    not exceed value of 10
    %.
    4.
    Acceptable basic error
    should be kept
    within limits shown
    for 8 h
    after the calibration.
    Photos
    If necessary we can take photos of a device from various angles.
    Technical Documentation
    In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you.
    Also I may speak directly with the manufacturer and find out more specific information about this product.
    If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
    On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
    In addition, translation of technical documentation into the customer’s language may be discussed.
    Delivery set
    On delivering the device will be completely ready for use.
    There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
    Warranty
    Warranty of this item
    - 12  month.
    Before sending a device, all devices are checked whether they comply with all technical specifications.
    Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
    If necessary, we can send you photos or video with the check-up process.
    I ship only fully working devices complying with all parameters.
    The warranty for this device is 1 year from the date of shipment from my warehouse.
    Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
    When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
    Within 1 year term we can advise you for free on the device operation.
    After-warranty service
    After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.
    Packaging
    Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
    If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
    A special handle will be made for ease of transportation.
    Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
    Discount (from-10% to -90%)
    I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.
    Unused cheap devices with the same specifications, accuracy and durability do not exist.
    If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.
    I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then
    I guarantee to sell you a unit at that cheaper price with additional 10% discount.
    Shipping details:
    Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
    I send goods via AirMailpost.
    App. delivery time :
    Europe – 7-15 days;
    USA, Japan&others – 10-20 days (depends on a country).
    I will ship in 10-15 business days after payment clearance.
    The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
    With express delivery you will mostly receive your goods within 3-7 working days.
    Payment details:
    I expect payment in 4 days after the auction ends.
    I accept a PayPal payment as the safest way of payment (preferably).
    If you do not have a PayPal account you can pay by wire transfer to my credit card.
    Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
    (This will be an official purchase on eBay).
    Please, tell me if you cannot pay in time, we can always negotiate it.
    When purchasing a few items, you’ll save on shipping.
    Return policy:
    I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
    I will refund your costs or send you the other item, as you wish (
    after I receive the previous item
    ).
    Please only serious bidders!